Cleaning Validation Protocol
for Sample Container
Learn how to validate the cleaning
procedure of sample container using spectrophotometer.
1. PURPOSE:
This is to establish the documented evidence to verify the
consistent performance of the Cleaning process of Sample Container for all
Spectroscopy analysis.
2. SCOPE:
This protocol is applicable to carry out the process validation of
Cleaning to ensure the Sample Containers has no residues to mix up with other
reagents used in QC Lab.
3. ABBREVIATION:
NA
- Not Applicable
NMT
- Not More Than
PPT
- Parts Per
Thousand
QA
- Quality Assurance
QC
- Quality Control
4. RESPONSIBILITY:
· It is the responsibility of Quality
personnel to prepare the protocol and execute the validation process as per
this protocol.
· It is the responsibility of Quality
Control Manager to review the protocol.
· It is the responsibility of QA Manager
to approve the protocol.
5. INTRODUCTION:
Sample
Containers used for Spectroscopy analysis
are subjected to Cleaning to ensure that no mix-up of the reagents occurs.
6. DOCUMENTATION:
NA
7. EQUIPMENT/
MATERIALS REQUIRED:
· Spectrophotometer
· Sample Container
· Conductivity Meter
· pH Meter
· Washing Solution
· Distilled Water
· Reagent (Coloured Reagent preferred)
8. PROCEDURE:
NEW SAMPLE CONTAINER (20mL / 50mL):
· Take a fresh new Sample Container and
Rinse with Distilled water twice (Holding Time 30 Seconds)
· Fill 20 mL of Distilled water in 50 mL
Sample Container and measure the absorbance at 505 nm, Conductivity, pH, TDS
and Salinity.
USED SAMPLE CONTAINER:
1.
Take a fresh new Sample Container and Rinse with Distilled water twice
(Holding Time 30 Seconds).
2.
Fill 20 mL of reagent in 50 mL Sample Container and measure the
absorbance at 505 nm, Conductivity, pH, TDS and Salinity.
3.
After measurement, take the same Sample Container, Rinse with Distilled
water twice (Holding Time 30 Seconds).
4.
Fill 20 mL of distilled water in Sample Container and measure the
absorbance at 505 nm, Conductivity, pH, TDS and Salinity.
5.
After measurement, take the same Sample Container, Rinse with washing
solution and then rinse with distilled water twice (Holding Time 30 Seconds).
6.
Fill 20 mL of distilled water in Sample Container and measure the
absorbance at 505 nm, Conductivity, pH, TDS and Salinity.
9. ACCEPTANCE
CRITERIA:
Parameter
|
Absorbance at 505 nm
|
pH
|
Conductivity
|
TDS
|
Salinity
|
New Sample Container with distilled
Water
|
NMT 0.000
|
5.0 to 7.0
|
1.3 µS/cm
|
0.5 to 1.5 mg/L
|
NMT 0.05 ppt
|
Used Sample Container with distilled
Water
|
NMT 0.003
|
5.0 to 7.0
|
1.3 µS/cm
|
0.5 to 1.5 mg/L
|
NMT 0.05 ppt
|
10. RECORD
OF RESULTS:
Table 1: Result for New Sample Container containing distilled
water.
New Fresh Sample Container(1)
|
Absorbance at 505 nm
|
Conductivity
(µS/cm)
|
pH
|
TDS
(mg/L)
|
Salinity
(ppt)
|
1
|
|||||
2
|
|||||
3
|
|||||
Average
|
Table 2: Result for used Sample Container containing reagent.
Used Sample Container(2)
|
Absorbance at 505 nm
|
Conductivity
(µS/cm)
|
pH
|
TDS
(mg/L)
|
Salinity
(ppt)
|
1
|
|||||
2
|
|||||
Average
|
Table 3: Result for used Sample Container containing
distilled water after washing (with distilled water).
Used Sample Container(2) after
washing
|
Absorbance at 505 nm
|
Conductivity
(µS/cm)
|
pH
|
TDS
(mg/L)
|
Salinity
(ppt)
|
1
|
|||||
2
|
|||||
3
|
|||||
Average
|
Table
4: Result for used Sample Container containing distilled water after washing
(with distilled water and washing solution).
Used Sample Container(2) after
washing
|
Absorbance at 505 nm
|
Conductivity
(µS/cm)
|
pH
|
TDS
(mg/L)
|
Salinity
(ppt)
|
1
|
|||||
2
|
|||||
3
|
|||||
Average
|
Table
5: Summary report of Sample Containers
S.No
|
Sample Containers
|
Absorbance at 505 nm
|
Conductivity
(µS/cm)
|
pH
|
TDS
(mg/L)
|
Salinity
(ppt)
|
1
|
New
Fresh Sample Container(1)
|
|||||
2
|
Used
Sample Container(2)
|
|||||
3
|
Used
Sample Container(2) after washing-1
|
|||||
4
|
Used
Sample Container(2) after washing-2
|
11. SUMMARY
REPORT: Measured values of Absorbance at 505 nm, Conductivity, pH,
obtained for fresh Sample Container (1 & 2) were meeting the acceptance
criteria, where absorbance at 505 nm of fresh Sample Container 1 containing
distilled water is 0.0000 and fresh Sample Container 2 containing distilled
water after washing with distilled water and washing solution
is …………..
12. CONCLUSION: The
Sample Container has been validated as per the protocol and it is
The overall Cleaning process is Satisfactory /
Not satisfactory
No comments:
Post a Comment