Electrical Inspection & Testing Basics ๐ฅ
As per Shri SKB Valli sir all Electrical inspection equipment must be listed and all time good condition with calibration certificates
Common Electrical Test Equipment – What to use, where, and why
Electrical testing verifies safety, performance, and reliability by comparing measured values against expected results—helping reduce defects, failures, and nonconformities.
1. Multimeter (VOM)
• Use: Measures voltage, current, resistance
• Range: mV to kV | ยตA to A
• Where: Panels, motors, wiring, appliances
• Detects: Open circuits, short circuits, wrong voltage
2. Megohmmeter (Megger)
• Use: Insulation resistance testing
• Range: 250V – 15kV
• Where: Cables, transformers, switchgear, breakers
• Detects: Moisture, insulation degradation
3. DLRO (Low Resistance Ohmmeter)
• Use: Measures very low resistance
• Range: ยตฮฉ to <1ฮฉ (up to 100A)
• Where: Busbars, joints, contacts, windings
• Detects: Loose or high-resistance connections
4. Ground Resistance Tester
• Use: Measures earth resistance
• Range: mฮฉ to kฮฉ
• Where: Substations, towers, buildings
• Detects: Poor earthing, unsafe grounding
5. Power Recorder / Power Quality Analyzer
• Use: Records voltage, current, power quality
• Range: System dependent (LV to HV)
• Where: Panels, feeders, substations
• Detects: Sags, swells, harmonics, PF issues
6. Hipotential (Hi-Pot) Test Set – AC / DC / VLF
• Use: Dielectric withstand testing
• Range: 1kV – 100kV+
• Where: HV equipment, cables, motors
• Detects: Weak insulation, leakage paths
7. Power Factor Test Set
• Use: AC insulation diagnostic
• Range: Up to ~12kV
• Where: Transformers, bushings, CT/PT
• Detects: Moisture, contamination, internal partial discharge
8. Winding Resistance Test Set
• Use: Measures winding resistance
• Range: 1A – 50A
• Where: Transformers, motors
• Detects: Loose connections, winding faults
9. Transformer Turns Ratio (TTR) Tester
• Use: Measures transformer winding ratio
• Range: Excitation <100V
• Where: Power & distribution transformers
• Detects: Winding faults, wrong connections
10. High Current Test Set (Primary Injection)
• Use: Tests breaker tripping under load
• Range: 500A – 15,000A+
• Where: Circuit breakers, protection systems
• Detects: Incorrect trip timing, faulty protection
11. Secondary Injection Test Set / Relay Test Set
• Use: Simulates fault conditions & tests relay logic
• Range: Variable voltage, current, frequency
• Where: Protection relays, IEDs, digital breakers
• Detects: Incorrect settings, malfunctioning protection logic
๐ง Right test. Right equipment. Right decision.