Sunday, 28 September 2025

Major safety during PV plant maintenance

 Major safety during PV plant maintenance involves comprehensive electrical isolation, Lockout/Tagout (LOTO) procedures, proper PPE, site hazard assessment for cable/module work, communication protocols, and emergency response plans for tasks like grass cutting, inverter breakdowns, and transformer replacements. 

General Safety During PV Plant Operations & Maintenance

Electrical Safety: Always assume all conductors are live until tested and verified. Use voltage-rated insulated tools and equipment. 

PPE: Wear appropriate Personal Protective Equipment (PPE), including arc-rated clothing, safety glasses, gloves, and fall protection if working at height. 

Site Hazard Assessment: Conduct a thorough assessment before any work to identify electrical, mechanical, and environmental hazards. 

LOTO: Implement strict Lockout/Tagout procedures to prevent accidental re-energization of equipment. 

Communication: Establish clear communication protocols, especially when multiple teams or contractors are working simultaneously. 

Training: Ensure all personnel are adequately trained on procedures, equipment, and emergency responses. 

Specific Activity Safety

Cable Rectification & Module Replacement:

Isolate: De-energize and isolate DC and AC power sources for the specific string or section. 

Verify Zero Energy State: Confirm the absence of voltage with a properly rated meter. 

Use Insulated Tools: Prevent accidental short circuits. 

Non-SCB Communication:

Isolate Power: Disconnect power to the affected SCB and associated communication equipment. 

Diagnose: Check for physical damage to communication cables or equipment, and update firmware as needed. 

Grass & Bush Cutting:

Ground Obstacles: Clear the area of loose equipment, cables, or tools that could be damaged or create hazards. 

Identify Underground Cables: Mark and avoid underground electrical cables during cutting operations to prevent contact. 

Major Breakdown of Inverter:

Secure the Area: Isolate the affected inverter and associated equipment, applying LOTO. 

Diagnose: A qualified technician should diagnose the issue, checking input voltage and system firmware. 

Consult Manufacturer: Seek assistance from the inverter manufacturer for complex issues or component replacement. 

Transformer Replacement:

High Voltage Hazard: Transformers pose significant risk from high voltage and stored energy. 

Rigorous LOTO: Implement a very strict LOTO procedure to ensure complete de-energization and verification. 

Specialized Equipment: Use appropriate heavy lifting equipment and follow procedures for safely removing and installing the transformer. 