PM162M
Automatic Sequential Particulate Sampler (TSP / PM10 / PM2.5 / PM1)
- Sampling through PM10, PM2.5, PM1 and TSP size selective inlets
- Sampling of particulate matter for heavy metals analysis
- Indoor air sampling
- Field survey before setting up of a continuous analyzer
- Follow-up of a specific pollutant
- Designed to automatically sample particulate on a filter using a TSP, PM2.5 or PM1 inlet
- 5U rack for installation in a rack cabinet or other type of cabinet
- Large filter holder capacity allowing up to 3 weeks of unattended sampling of particulate matter
- Compliant with the last EU CEN recommendations for PM2.5 sampling and measurement
- True volumetric air flow control with atmospheric temperature and pressure sensors to avoid artifacts in the size fractionating inlet
- Exclusive temperature-regulated sampling tube to avoid artefacts on the filter (evaporative losses of semi-volatile particulale matter...)
- Interactive user-friendly multi-task software
- 2 serial ports for remote access and downloading of stored data
- Filter holder capacity: 22 filter cassettes
- Filter diameter: 47mm
- Filtering diameter: 40 mm (EN12341 compliant)
- Flow rate: 2.3m3/h or 1m3/h (user selectable)
- Filter temperature measurement
MP101M (CPM option)
Ambient air suspended particulate analyzer, with real time measurement option (CPM)
- Ambient air quality monitoring
- Indoor dust monitoring
- Working places
- Industrial areas
- True particulate concentration measurement, not influenced by the
- physico-chemical nature, color or shape of particulates
- True volumetric air flow control with atmospheric temperature and pressure sensors to avoid artefacts in the size fractionating inlet
- Real time optical counting of PM10, PM2.5 & PM1 (nb/cm3) and measurement of the concentration (μg/m3)
- Direct integration of CPM on MP101M between the inlet of the analyzer and the RST sampling tube (temperature-regulated to avoid evaporative losses of semi-volatile particulate matter)
- Calibration of the real time concentration measurement against the reference measurement (ß gauge) : CPM recalibration unnecessary
- Exclusive patented optical technology, guaranteing strictly no interference due to particulate nature
- Direct measurement of particulate concentration by granulometric size family PM10, PM2.5, PM1
- Measurement ranges: 0- 100 / 0- 200 / 0- 500 / 0- 1000 / 0- 2000 / 0- 5000 / 0- 10000 µg/m3(Beta gauge)
- Cycle time: 1/ 4, 1/ 2, 1, 2, 3, 6, 12, 24 h selectable
- Source: sealed Carbon 14, half lifetime: 5000 years, low activity: < 3.33 MBq (90 µCi)
- Measurement ranges: 0- 1500 µg/m3 (optical)
- Complies with ISO 10473 :2000
- United States : US EPA, EQPM - 0404 - 151
- Russia : GOSSTANDART, 1787
- Italy : Certification CNR d'équivalence à l'EN 12341 n°87/2004
- Europe : Certified equivalent to PM10 measurement Reference Method according to EN 12341 (CNR 087/2004)
PM10 sampling inlet used along with
Model MP 101M
- United States : EPA, RFPS - 0789 - 073
- Europe : complies with EN 12341 standard
No comments: