Tuesday, 15 May 2012

PM162M Automatic Sequential Particulate Sampler (TSP / PM10 / PM2.5 / PM1)

PM162M

Automatic Sequential Particulate Sampler (TSP / PM10 / PM2.5 / PM1)

 

  • Sampling through PM10, PM2.5, PM1 and TSP size selective inlets
  • Sampling of particulate matter for heavy metals analysis
  • Indoor air sampling
  • Field survey before setting up of a continuous analyzer
  • Follow-up of a specific pollutant
  • Designed to automatically sample particulate on a filter using a TSP, PM2.5 or PM1 inlet
  • 5U rack for installation in a rack cabinet or other type of cabinet
  • Large filter holder capacity allowing up to 3 weeks of unattended sampling of particulate matter
  • Compliant with the last EU CEN recommendations for PM2.5 sampling and measurement
  • True volumetric air flow control with atmospheric temperature and pressure sensors to avoid artifacts in the size fractionating inlet
  • Exclusive temperature-regulated sampling tube to avoid artefacts on the filter (evaporative losses of semi-volatile particulale matter...)
  • Interactive user-friendly multi-task software
  • 2 serial ports for remote access and downloading of stored data

  • Filter holder capacity: 22 filter cassettes
  • Filter diameter: 47mm
  • Filtering diameter: 40 mm (EN12341 compliant)
  • Flow rate: 2.3m3/h or 1m3/h (user selectable)
  • Filter temperature measurement

MP101M (CPM option)

Ambient air suspended particulate analyzer, with real time measurement option (CPM)

 

  • Ambient air quality monitoring
  • Indoor dust monitoring
  • Working places
  • Industrial areas
  • True particulate concentration measurement, not influenced by the
  • physico-chemical nature, color or shape of particulates
  • True volumetric air flow control with atmospheric temperature and pressure sensors to avoid artefacts in the size fractionating inlet
  • Real time optical counting of PM10, PM2.5 & PM1 (nb/cm3) and measurement of the concentration (μg/m3)
  • Direct integration of CPM on MP101M between the inlet of the analyzer and the RST sampling tube (temperature-regulated to avoid evaporative losses of semi-volatile particulate matter)
  • Calibration of the real time concentration measurement against the reference measurement (ß gauge) : CPM recalibration unnecessary
  • Exclusive patented optical technology, guaranteing strictly no interference due to particulate nature
  • Direct measurement of particulate concentration by granulometric size family PM10, PM2.5, PM1
  •  
  • Measurement ranges: 0- 100 / 0- 200 / 0- 500 / 0- 1000 / 0- 2000 / 0- 5000 / 0- 10000 µg/m3(Beta gauge)
  • Cycle time: 1/ 4, 1/ 2, 1, 2, 3, 6, 12, 24 h selectable
  • Source: sealed Carbon 14, half lifetime: 5000 years,  low activity: < 3.33 MBq (90 µCi)
  • Measurement ranges: 0- 1500 µg/m3 (optical)
  •  
    Complies with  ISO 10473 :2000
  • United States : US EPA, EQPM - 0404 - 151
  • Russia : GOSSTANDART, 1787
  • Italy : Certification CNR d'équivalence à l'EN 12341 n°87/2004
  • Europe : Certified equivalent to PM10 measurement Reference Method according to EN 12341 (CNR 087/2004)
 
PM10 sampling inlet used along with Model  MP 101M
  • United States : EPA, RFPS - 0789 - 073
  • Europe : complies with EN 12341 standard
 