Res. Environ. Life Sci., 4(1) 7 -12 (2011)
Capturing CO2 from flue gas streams in ammonia plant,
waste generation as HSS and its reclamation at CO2 recovery plant,
NFCL, Andhra Pradesh (India)
R. Raghavan,
G.V.S Anand, P.H.N Reddy, P. Chandra Mohan, V. Appala Raju* and Amar Nath Giri**
Quality & Environment
Management System, NFCL, Nagarjuna Road, Kakinada - 533 003, India
e-mail: *varaju@nagarjunagroup.com, **amarnathgiri@nagarjunagroup.com
(Received:
October 24, 2010; Revised received: February 05, 2011; Accepted: February 08,
2011)
Abstract: There are a number of
different methods for Mitsubishi Heavy Industries (MHI) has
concentrated its extensive research and development programs on the use of sterically hindered amines and the post combustion,
chemical absorption process in particular for treating flue gasses
from natural gas combustion. The CO2 recovery plant consists
of three main sections: the flue gas cooler, the absorber (for CO2
recovery) and the stripper (for solvent regeneration). In NFCL Kakinada, the flue gas from primary reformer enters in
the flue gas quencher, where it is cooled to 40°C. The flue gas is compressed
to a pressure of 1.113 Ksca and enters in the CO2 absorber.
The CO2 in flue gas is absorbed by KS-1 (Hindered amine)
solvent, which is distributed from top through packed bed system. The CO2 thus
liberated is washed with DM water at the top of CO2 regenerator,
cooled to ambient temperature in an overhead condenser and sent to urea
plants.
Capturing CO2
from flue gas streams Ammonia Plant, waste generation as HSS and its
Reclamation at CO2 Recovery Plant, NFCL, Andhra Pradesh (India)
R. Raghavan, G.V.S Anand, P.H.N Reddy, P. Chandra Mohan, V.
Appala Raju and
Amar Nath Giri
Quality & Environment Management System, NFCL, Nagarjuna Road, Kakinada - Kakinada - 533 003, India
e-mail: varaju@nagarjunagroup.com, amarnathgiri@nagarjunagroup.com
Quality & Environment Management System, NFCL, Nagarjuna Road, Kakinada - Kakinada - 533 003, India
e-mail: varaju@nagarjunagroup.com, amarnathgiri@nagarjunagroup.com
Abstract: There are a number of different methods for Mitsubishi Heavy Industries (MHI) has concentrated its extensive research and development programs on the use of sterically hindered amines and the post combustion, chemical absorption process in particular for treating flue gasses from natural gas combustion. The CO2 recovery plant consists of three main sections: the flue gas cooler, the absorber (for CO2 recovery) and the stripper (for solvent regeneration). In NFCL Kakinada, Andhra Pradesh, India the Flue Gas from Primary Reformer enters the Flue Gas Quencher, where it is cooled to 40°C. The Flue Gas is compressed to a pressure of 1.113 Ksca and enters the CO2 Absorber. The CO2 in Flue Gas is absorbed by KS-1 (Hindered Amine) Solvent, which is distributed from top through packed bed system. The CO2 thus liberated is washed with DM water at the top of CO2 Regenerator, cooled to ambient temperature in an overhead condenser and sent to Urea Plants.
KEY WORDS: Flue gas, carbon dioxide
recovery plant, chemical absorption, Heat Stable salts,
Introduction:
As Wong and Bioletti (1999), the emission of carbon
dioxide (CO2) from the burning of fossil fuels has been identified as the major
contributor to global warming and climate change. However, for the
immediate term over the next 20 – 30 years at least, the world will continue to
rely on fossil fuels as the source of primary energy. The challenge for the fossil fuel
industry is to find
cost-effective solutions that will reduce the release of CO2 into the atmosphere. Reduction of anthropogenic CO2 emissions into the atmosphere can be achieved by
a variety of means, which has been summarized by Professor Yoichi Kaya of the
University of Tokyo and can be expressed as: Where CO2 the total released to the
atmosphere, POP is population, GDP
(Gross Domestic Product) /POP ( population) is
per capita gross domestic product and is a measure of the standard of living, BTU/GDP is energy
consumption per unit of GDP and is a measure of energy
intensity, CO2⇑⇑/BTU is the amount of CO2 released per unit of energy
consumed and is a measure of carbon intensity, and CO2⇓is the amount of CO2 stored/sequestered in biosphere
and geosphere sinks.
Of the first two measures,
reducing the population or the standard of living is not likely to be
considered. Consequently, only the three remaining methods can be employed
(i.e. reducing
energy intensity, reducing carbon intensity and carbon storage).
Mimura
et. al., (2001) describe their recent work in solvent
composition. They have developed a series of amine solvents designated as KS-1, KS-2, and KS-3 as improved
Hindered Amine) The composition of these solvents is propriety. The KS-1
solvent has been commercialized in Malaysia where a flue gas
containing 8 vol. % CO2 is
being treated with 90% CO2 recovery.
Corrosion problems were reported to be negligible using this solvent and also
that solvent degradation during prolonged operation was slight. They indicated
that amine consumption was about 2.0 kg/ton CO2 recovered using a MEA
process while for the Malaysia
plant using KS-1, solvent loss was 0.35 kg/ton CO2 recovered. With improved
solvents currently in the pilot phase, they indicate that solvent loss may be
further reduced to ~0.1 kg/ton CO2 recovered. Steam consumption was 1.5 ton of low-pressure steam per ton CO2 recovered. It is claimed
that K-3 is better than K-1 and K-2 in terms of energy consumption for solvent
regeneration. A pilot plant test using
KS-3 under coal fired boiler flue gas containing 14-vol% CO2 (dry basis) and 50 ppm SOx showed a CO2 recovery of 90% (Mimura et al.,
1999), and sodium hydroxide was believed to be used in the solvent regeneration
by converting the heat-stable salt due to reaction of SOx with the amine to free amine and
Na2SO3. The Canadian group has also developed a
series of proprietary designer solvents designated as PSR solvents (Veawab et al., 2001). The PSR solvents have been designed to
specifically for the separation of CO2 from
flue gas streams. The PSR solvents may be used at higher amine concentration
than conventional MEA solvents and at a higher loading of CO2. The
key features claimed for the PSR solvents are lower regeneration temperature,
lower solvent circulation rate, lower solvent degeneration rate, and lower
corrosion rate.
Materials and Methods:
CO2 capture Process in CDR plant: The flue gas is from a
natural gas fired application an FGD may not be required as the SO2
content in the gas stream is minimal. Therefore, depending on the fuel type, a
Deep FGD process may or may not be necessary. The primary objective of the Flue
Gas Water Cooler (FGWC) is to further cool the flue gas prior to entering the CO2 absorber. The lower flue gas
temperature increases the
efficiency of the exothermic CO2 absorption reaction and minimizes
KS-1(TM) solvent loss due to gas phase equilibrium increases. The optimum
temperature range for CO2
recovery is between 95-113°F (35-45°C), however this is flexible in
consideration of other factors such as water utility requirements and
availability. The FGWC is designed and constructed to not only to cool the flue
gas, but to also further remove various impurities such as SOx, NOx, dust and
suspended particulate matter (SPM).Clean-burning, natural gas typically has low
concentrations of CO2
and impurities. The CO2
Absorber has two main sections, the CO2
absorption section (bottom section), and the treated flue gas washing section
(top section). The conditioned flue gas from the FGWC flows upward through
structured, stainless steel packing material while the CO2 lean KS-1 solvent is
distributed evenly from the top of the absorption section onto the packing
material. The flue gas comes into direct contact with the KS-1(TM) solvent and CO2 in the flue gas is
absorbed. The CO2 rich
KS-1(TM) solvent (rich solvent) is pumped to the CO2 Regeneration unit for
steam stripping. The clean flue gas then moves up into the treated flue gas
washing section of the absorber. This section is where vaporized KS-1 solvent
is removed and recycled and the flue gas is again cooled to maintain water
balance within the system (the absorption of CO2 in the KS-1 solvent produces some rise in
temperature). The clean flue gas then exits the top section of the CO2Absorber. The rich
solvent is pre-heated in a heat exchanger using heat from the hot lean solvent
coming from the bottom of the CO2
Stripper. The heated rich solvent is then introduced into the upper section of
the CO2Stripper,
where it will come into contact with stripping steam of around 248°F (120°C).
The rich solvent is then stripped of its CO2 content and is converted back into
lean solvent. The high purity CO2
(>99.9%) exits the top of the stripper vessel and is compressed and
dehydrated, prior to transportation. Once stripped, the now lean solvent is
cooled to the optimum reaction temperature of approximately 104°F (40°C) before
being reintroduced to the top of the absorption section of the CO2 Absorberunit.
CDR Plant Opted at NFCL (Technology Supplier: Mitsubishi
Heavy Industries (MHI),
Japan.CO2 Absorbent:
KS-1 Solution, Proprietary Supply from MHI, Japan): The Flue Gas from Primary
Reformer enters the Flue Gas Quencher, where it is cooled to 40°C. The Flue Gas
is compressed to a pressure of 1.113 Ksca and enters the CO2 Absorber. The CO2 in Flue Gas is absorbed by KS-1
Solvent, which is distributed from top through packed bed system. Subsequent to
contact with KS-1 Solution the Flue Gas is further washed with DM Water in the
top section of CO2 Absorber. The Flue Gas after removal of CO2 is sent out to atmosphere through a
stack provided at CO2Absorber top. The CO2 rich solution at 55°C is pumped to the
Lean / Rich Heat Exchanger. The Lean Solution is recycled back to CO2 Absorber. The rich solution stream is
heated up to 114 °C and sent to CO2 Regenerator, wherein CO2 is stripped off from rich solution by
providing necessary heat to Reboiler using Low Pressure Steam. The CO2 thus liberated is washed with DM water
at the top of CO2 Regenerator,
cooled to ambient temperature in a overhead condenser and sent to Urea Plants.
In
view of adequate Natural Gas supply
to NFCL by RIL, it was decided to switchover Unit-II operations to full NG mode
from the present operation of mixed Feed / Fuel (NG + Naphtha). Subsequent to
switchover from Naphtha / NG Mix to full Natural Gas mode in Unit-II, there
will be shortfall of CO2 which
will be met through the CO2 Production
from CDR Plant.
The Power & Steam
demand required for CDR Plant is met through the existing offsite facilities. The flue gas having about 8
to 9% CO2 by volume is
drawn from Primary Reformer stack and cooled to 45°C or below in a Direct
Contact Cooler. It is then fed at the bottom of an absorber through a blower.
The absorber is a packed tower. A solvent mainly KS1 is fed on the top of the
absorber. The solvent and rising flue gas come in contact on the bed. The
solvent absorbs CO2 from
the flue gas and balance flue gas devoid of CO2 is vented from the top of the absorber
after washing. The solvent after
absorption of CO2 becomes
rich and collected at the bottom of the absorber. The rich solution is pumped
to the top of a regenerator after heat exchange where heat of regeneration is
supplied through a re-boiler. On heating, the solution liberates absorbed CO2 and solution gets regenerated for
further absorption. The CO2 is
collected from the top of the regenerator and sent to Urea plant through a
booster compressor for further conversion to Urea.
In this process some heat stable salts are generated due to minor decomposition of the solvent which is separated in a reclaimer and disposed off.
In this process some heat stable salts are generated due to minor decomposition of the solvent which is separated in a reclaimer and disposed off.
Solvent (KS1 Solution) using for Recovery in CDR plant &
its Environmental consequences: These factors contribute to
the use of large equipment, high solvent consumption and large energy losses -
leading to increased operating costs. During its comprehensive R & D
phases, MHI tested more than 130 different reagents. The most efficient
solvents were critically examined in the final stage of pilot plant testing. Following this, a proprietary
solvent KS- 1(TM) was developed. In parallel with the development of the
solvent, the process itself has also
been optimized, leading to superior, demonstrated performance of CO2 recovery
from the flue gases of fossil fuel combustion processes. The development of
KS-1(TM) is seen as a breakthrough because of the significant number of advantages it offers.
KS-1(TM) has an exceptionally low corrosive nature and, unlike MEA, does not
require a corrosion
inhibitor. This factor means carbon steel can be used for the majority of
construction within the CO2 capture plant. Furthermore, the process
operates at atmospheric pressure (ensuring a safe work environment), has few
exotic materials and a simple configuration. Additionally KS-1(TM) offers
superior CO2 absorption and
regeneration, lower degradation, lower circulation rate and, with other
patented equipment, has less solvent loss when compared to other amine based
systems. All of these features lead
to decreased operating cost. Importantly, KS-1(TM) together with the patented
"improved" CO2 recovery process
which utilizes the heat of the lean KS-1(TM) solvent, effects a 30% reduction
in steam consumption over the conventional MEA process.
HSS (Heat Stable Salt): Heat Stable Salts (HSS)
have received a lot of attention in the industry. HSS are acid anions with a stronger acid strength than
the acid gases that are removed from the process gas. These anions may bind to
the usable amine and then therefore make it unavailable for acid gas absorption. Heat Stable Amine Salts
(HSAS) refers to the salt formed by a HSS (anion) and a protonated amine
molecule (cation). HSAS may also be referred to in some instances as Bound
Amine (BA)
HSS vs. HSAS: There has been much
confusion about the terminology of HSS versus HSAS. It is important to
understand that these HSS anions must be bound to a cation in solution so that
the solution is balanced (Mother Nature’s Rule). One must understand what
cation forms a salt with the HSS anion to understand the disposition of the
anions and their quantity in solution. As referred to earlier, the sum of
cations in solution must equal the amount of anions in solution.
Σ
Cations = Σ Anions
BA + SC = HSS + LL
BA = Bound Amine (Protonated Amine Molecule)
SC = Strong Cations (Sodium or Potassium)
HSS = Heat Stable Salt Anions
LL= Residual Lean Loading (H2S or CO2)
BA + SC = HSS + LL
BA = Bound Amine (Protonated Amine Molecule)
SC = Strong Cations (Sodium or Potassium)
HSS = Heat Stable Salt Anions
LL= Residual Lean Loading (H2S or CO2)
From
the above equation we can see that HSS will not equal the Bound Amine (HSAS) if
there is a substantial amount of Strong Cations present in the amine solution.
This is why we recommend that the total level of HSS anions and Strong Cations
should be measured directly. Measuring the HSAS only may give a false low
reading of the level of HSS anions in solution if Strong Cations are also
present in the sample.
It
is also important to understand that HSS anions may be reported at least three
different ways, and it is important to understand the methodology employed to
avoid confusion.
1.
Weight Percent of Solution HSS Anions (Strong Acid Anions) measured as weight
percent of the total solution.
2. As Weight Percent Amine This unit of measurement assumes that the HSS anions are bound to an amine cation (also reported as HSAS, Heat Stable Amine Salt). This number is determined by calculating the equivalent amount of amine cations that are tied up with the HSS anion, and is expressed as weight percent of the total solution.
3. As Percent Amine Capacity (As Percent Total Amine) HSS expressed as weight percent amine divided by the amine strength (Free Amine or Alkalinity).
2. As Weight Percent Amine This unit of measurement assumes that the HSS anions are bound to an amine cation (also reported as HSAS, Heat Stable Amine Salt). This number is determined by calculating the equivalent amount of amine cations that are tied up with the HSS anion, and is expressed as weight percent of the total solution.
3. As Percent Amine Capacity (As Percent Total Amine) HSS expressed as weight percent amine divided by the amine strength (Free Amine or Alkalinity).
Determination and analysis Procedure of Heat Stable salts:
Method: This method is intended to
be used to determine the quantity of heal
stable salts present in used
aqueous amine solutions. A weighed sample of solvent is passed through (or
equivalent) a column of DOWEX* 50W-X8, 50-100 mesh hydrogen form resin. The
anions present are converted to the corresponding acids, and the solvent is
retained or. the resin. The effluent containing the acid is then titrated,
potentiomctricully, with a standard base.
Apparatus: pH
meter,
with a combination pH electrode, Glass column, ID 16mm x 610mmL, or
100ml ion exchange column, Stand for ion exchange column, Magnetic stirrer with
heater, Thermometer (0—100°C), Beaker, Capacity 200ml, 500ml, 31, Automatic
titrator, Plastics funnel, Electric balance, graduated at lmg
Reagents
(1) 0.IN NaOH solution Dissolve 4~4.5g of NaOH in \ liter of water. Make standardization as follows.
Reagents
(1) 0.IN NaOH solution Dissolve 4~4.5g of NaOH in \ liter of water. Make standardization as follows.
·
Weigh 0.2~0.25g of sulfamic acid and dissolve the acid in 50ml
of water.
·
Add 3 drops of Bromothymol blue (BTB)
solution and titrate the solution until the color of solution turns blue.
·
Normality of 0.1N NaOH solution is calculated as follows.
N= SF/ 97.09 X 103 /V
Where, N: normality of 0.1N NaOH solution (eq/1) SF: weight to taken sulfamic acid (g) V: 0.1N NaOH solution consumed; in titration (ml)
(2) 0.1% Bromothymol blue
(BTB) indicator Dissolve 0.l g of BTB in
20ml of ethyl alcohol. Then, dilute to 100 ml with water.
(3) Hydrochloric
acid (5 or 10%)
(4) Cation exchange
resin (Hydrogen form)
(5) pH paper, range to
include 6~8.
Procedure:
1)
Fill the glass column with enough wet resin to completely neutralize the
solvent and exchange the anions present. (Approximately 2 ml of resin per meq.
of solvent.)
2)
Pass 100ml of 10% HCl through the resin and rinse with deionized water
until the effluent is neutral to pH paper.
3)
Combine 5~10 grams of sample plus or minus one milligram, 50ml of resin and 50
ml of deionized water.
4)
Heat to at least 71°C for 30minutes.
5)
Add another 50 ml of resin to column.
6)
Pour entire solution (Including resin) into resin column and follow with
deionized water until the liquid eluting from the column is neutral to pH
water.
7)
Combine the rinse water, the eluted sample, and titrate potentiometrically with
0.1 N sodium hydroxide solutions with automatic titrator.
8)
From the titration
curve obtained, determine
the greatest point of inflection and consider this to be the end point, that is,
the number of milliliters required for complete titration of the system.
9)
Make the blank test over the whole procedure and correct the result.
Calculation
From the quantity of 0.1 N NaOH solution consumed in the titration, the acidity and the concentration of heat stable salts can be calculated as follows.
From the quantity of 0.1 N NaOH solution consumed in the titration, the acidity and the concentration of heat stable salts can be calculated as follows.
(1)
Acidity
A = (a-b)xN
W5
Where, A : acidity in sample (eq/kg)
a: 0.1 N NaOH solution consumed in titration in sample test (nil)
W5
Where, A : acidity in sample (eq/kg)
a: 0.1 N NaOH solution consumed in titration in sample test (nil)
b: 0.1 N NaOH solution consumed in titration in blank test (m )
Ws:
weight of sample taken (g)
N:
normality of 0.1 N NaOH solution (eq/1)
(2) Heat
stable salts (HSS) concentration HSS (eq/kg) = A
Remarks
1) If the solution contains carbonates and/or sulfides, in addition to the free acid gases present, voids can form in the column from release of the CO2 and H2S, and subsequent channeling will occur. By slurring the sample in a beaker with an additional quantity of resin, until the mixture is acid, the gases will be evolved. The mixture can then be poured over the resin in the column and the determination followed in the normal fashion.
2) Before the titration is made, it is advantageous to boil the effluent sample, with vigorous stirring, for a few minutes. This will allow any dissolved acid gases to escape which would buffer the titration. The acids formed from the ion exchange are not affected by this boiling.
3) Quantitative analysis for many of the anions found in solvent systems can be made on the titrated effluent, as interference from the solvent and ether cations have been removed by absorption on the resin.
4) After the resin has been in contact with a 1 N (or stronger) hydrochloric acid solution for a sufficient length of time, it will attain an equilibrium exchange capacity of about 1 meq/ml of wet resin. In order to avoid column breakthrough, never exchange more than half the original capacity of the resin. Thus, it is best to provide initially a 100% excess of resin capacity over and above the quantity thought to be necessary.
Remarks
1) If the solution contains carbonates and/or sulfides, in addition to the free acid gases present, voids can form in the column from release of the CO2 and H2S, and subsequent channeling will occur. By slurring the sample in a beaker with an additional quantity of resin, until the mixture is acid, the gases will be evolved. The mixture can then be poured over the resin in the column and the determination followed in the normal fashion.
2) Before the titration is made, it is advantageous to boil the effluent sample, with vigorous stirring, for a few minutes. This will allow any dissolved acid gases to escape which would buffer the titration. The acids formed from the ion exchange are not affected by this boiling.
3) Quantitative analysis for many of the anions found in solvent systems can be made on the titrated effluent, as interference from the solvent and ether cations have been removed by absorption on the resin.
4) After the resin has been in contact with a 1 N (or stronger) hydrochloric acid solution for a sufficient length of time, it will attain an equilibrium exchange capacity of about 1 meq/ml of wet resin. In order to avoid column breakthrough, never exchange more than half the original capacity of the resin. Thus, it is best to provide initially a 100% excess of resin capacity over and above the quantity thought to be necessary.
Results:
Analysis
items and frequency are shown below. The analysis item and / or frequency may be
increased depending upon the requirement in an operating facility.
IRON & HSS Analysis report as Monthly Average it its trend of growth
IRON & HSS Analysis report as Monthly Average it its trend of growth
|
KS1 solution ( After
Correction of the data)
|
|
May 2009-Jan.2011
|
Iron (ppm)
|
HSS (%) Analysis Result is this
|
May, 09
|
1.1
|
0.1
|
June, 09
|
3.2
|
0.3
|
July, 09
|
4.7
|
0.5
|
August, 09
|
5.5
|
0.6
|
September, 09
|
6.2
|
1.0
|
October, 09
|
6.2
|
1.2
|
November, 09
|
7.8
|
1.5
|
December, 09
|
8.5
|
2.1
|
January, 10
|
8.6
|
2.5
|
February, 10
|
13.5
|
2.7
|
March, 10
|
13.9
|
2.7
|
April, 10
|
16.45
|
3
|
May, 10
|
15.8
|
1.8
|
June, 10
|
14.0
|
1.4
|
July, 10
|
15.2
|
1.0
|
August, 10
|
12.5
|
0.9
|
September, 10
|
10.5
|
0.8
|
October, 10
|
7.0
|
0.6
|
November, 10
|
9.0
|
0.8
|
December, 10
|
19.5
|
1.15
|
January, 10
|
14
|
0.9
|
Discussion:
Several
researches have been found and develop Solvent to absorb CO2 which should be
cost effective & Economically Viable as per Mimura et., al (2004) [1] they have developed and
observed the alternative of KS1 Solvent as KS2: The most important issue
involved with the chemical absorption method for recovering carbon dioxide from
a power plant's flue gas is to develop energy-efficient absorbents. KS-1
absorbent was presented at ICCDR-2 in Kyoto.
After the conference, efforts to develop energy-efficient absorbents have been
made and a new absorbent KS-2 was developed as a result and its performance
confirmed by the pilot plant. KS-2 has similar energy efficiency as KS-1
both of which require 20% less energy than MEA. KS-2 is however more stable
than KS-1 and a more efficient absorbent for low CO2 content flue gas.
MHI
has published papers on the performance of its KS-1 solvent in the Petronas
Fertilizer Co. CO2 capture
plant in Malaysia.
This is the only commercial installation of KS-1. Using this data, the
performance of the EFG Plus SM technology can be compared to
KS-1. The recovery of carbon dioxide from the rich amine stream from the
absorber is highly energy intensive. It requires substantial quantities of low
pressure steam extraction from the power plant turbine cycle and high power
usage for compressing large volumes of flue gas to overcome absorber pressure
loss. This results in a significant export power loss. Technology developers
have therefore concentrated on developing new generations of technology which
minimize steam consumption, by ensuring that a high degree of thermal
integration is achieved in the process and/or by using amines with lower
stripping steam requirements, either with improved formulations (Fluor), or
improved amines (MHI with their KS1, 2 and 3 series of amines which have a much
lower specific stripping heat requirement than MEA). Fluor has developed an improved
process called Econamine FG PlusSM. Which lowers the energy
consumption of the process (Reddy et.al., 2003).
There is considerable
industrial experience with MEA and most systems at present use an aqueous
solution with only 15-25-wt% MEA, mainly due to corrosion issues. Corrosion
inhibitors may be added to
MEA solution, and these results in an increase in solution strength. In a
commercial process, concentration of MEA up to 30-wt% have been employed
successfully to remove 80% - 90% of the carbon dioxide from the feed gas (Mariz, 1998). The process has been
used to treat flue gas, however, some cooling and compression of the gas is
required to operate the system. The solvent composition is proprietary, so
royalty costs may be significant. Another commercial process, which uses 20%
MEA with inhibitors, is also offered for flue gas treatment (Barchas, 1992).
1. It
should be avoided to continue CDR plant operation without
reclaiming under the condition that iron
concentration is 11ppm. in the case that CDR plant continues to operate under
the condition that iron concentration is over 5ppm, CDR plant has a great risk of
corrosion. The allowable limit of iron concentration for starting reclaiming
shall be 5ppm.
2. Situation regarding the
increase of iron concentration, which was happened at IFFCO Phulpur, is
described below:
In 2007, iron concentration in KS-1 solution increased up to 32ppm.-MHI inspected inside after CDR plant S/D, and then found that heavy corrosion occurred at the duct between stack and Quencher. Quencher, Absorber and Regenerator had no corrosion. -After investigation into CDR plant operation, it was found that CDR plant S/D without drying operation caused this heavy corrosion, resulting in entrainment of iron dust to KS-1 solution. So, iron concentration in KS1 solution increased. Drying operation is necessary after CDR plant S/D for the purpose of preventing CDR plant corrosion.-MHI recommended duct coating against entrainment of iron dust, and drying operation after CDR plant S/D.The increase of iron concentration in KS1 solution had stopped since duct coating was conducted.
In 2007, iron concentration in KS-1 solution increased up to 32ppm.-MHI inspected inside after CDR plant S/D, and then found that heavy corrosion occurred at the duct between stack and Quencher. Quencher, Absorber and Regenerator had no corrosion. -After investigation into CDR plant operation, it was found that CDR plant S/D without drying operation caused this heavy corrosion, resulting in entrainment of iron dust to KS-1 solution. So, iron concentration in KS1 solution increased. Drying operation is necessary after CDR plant S/D for the purpose of preventing CDR plant corrosion.-MHI recommended duct coating against entrainment of iron dust, and drying operation after CDR plant S/D.The increase of iron concentration in KS1 solution had stopped since duct coating was conducted.
3. MHI
designs that reclaiming shall be started when HSS concentration reaches to
2wt%, and then stopped when it comes down to 0.7wt%. In NFCL case, HSS
concentration in KS1 solution is expected to increase as following figure based
on the design basis of the flue gas. 1st reclaiming should be therefore conducted
after approximately 2.5 months passed from CDR plant S/U. Next reclaiming
should be done when approximately 1.5 months passed after 1st reclaiming has
been finished.
In NFCL the formation of
HSS in CDR plant shows exponential growth from starting to till 05-05-10 ---3.3
(%)/ 2.9 (%) & the Iron Content was also very high around 18 ppm after then
due to alkanomisation / Reclamation the HSS quantity has been decreased
1.0% (21.08.10) now it is gradually Decreasing due to reclamation now it has been 0.9%
and the IRON content is around an around 14 ppm as per the Norms Of Mitsubishi KM it
should be below 0.7 % the query is if continuously analysis by Quality Control why it has not been reduced of Both
the HSS formation & Iron. As per my opinion it should be less than 1% ( We
have to maintain) & the Iron Content is also should be below 11 PPM for the
best performance of the CDR plant then we can increase the ATA -in 2011 May. We
are daily adding I Drum of KS1 solution around 200 litre & Additives to
make efficient the chemical properties of KS 1 Solution to absorb 2 molecule of
CO2
by one molecule of KS1 & to maintain the passivation layer to reduce the
Corrosion of the equipment
Acknowledgement: We are highly thankful to Production , process , Environment
& Quality Laboratory associates of
NFCL and for their consistently
support while Preparation of the Environment
& Quality paper.
Reference:
Barman,
S.C., G.C. Kisku, P.R. SaiveD. Misra, R.K. Sahu, P.W. Ramtake and S.K.
Bhargava: Assessment of industrial effluent and its impact on soil and plants. J. Environ. Biol., 22: 251-256 (2001).
Barchas, R., and Davis, R.,
: “The Kerr-McGee/ABB Lummus Crest Technology for the Recovery of CO2 from Stack Gases”, Energy
Convers. Mgmt., Vol. 33, No. 5-8, pp 333-340, 1992.
Mariz, C.L. (1998), “Carbon
Dioxide Recovery: Large Scale Design Trends”, Journal of Canadian Petroleum
Technology, Vol. 37, 7, July 1998.
Mimura, T., Simayoshi, H.,
Suda, T., Masaki Iijima and Sigeaki Mituoka: Development
of energy saving technology for fluegas carbon dioxide recovery in power plant by chemical
absorption method and steam system.http://www.sciencedirect.com/science (2004).
Mimura, T., Matsumoto, K.,
Iijima, M. & Mitsuoka, S., Fifth : Development and application of flue gas
carbon dioxide recovery technology, Proceedings
of International Conference on Greenhouse Gas Control Technologies, Cairns,
Australia, August 13-16, 2000, Published by CSIRO publishing, Collingwood,
Victoria, Australia.
Reddy, S., Scherffius, J.,
Freguia, J., Roberts, C.A., Fluor EFG+SM Technology,
An enhanced Amine Based CO2 Capture
Process, Original paper presented at Second
National Conference On Carbon Sequestration, NETL.DOE, Alexandria VA May 5-8, 2003.
Veawab, A., Aroonwilas, A.,
Chakma, A. and Tontiwachwuthikul, P.,: “Solvent Formulation for CO2 Separation from Flue Gas
Streams”. First National Conference on Carbon Sequestration, Washington, DC,
May 15-17, 2001.
Wong,
S., Gunter, W.D., and Bachu, S.,: “Geological Storage of CO2:
Options for Alberta”, Combustion and Global Climate
Change Conference, Calgary,
Alberta, May 26-28, 1999.