Groundwater is a major water source for many industrial units in India.
But using groundwater is not only an operational issue.
It is also a compliance issue.
For an EHS professional, the important questions are:
Are we legally permitted to abstract groundwater?
How much are we allowed to use?
Are we measuring it correctly?
Are we maintaining the required records?
Depending on the location and applicable regulatory framework, an industrial unit may need approval or NOC from the relevant groundwater authority, along with compliance with CTE, CTO or other conditions.
Once groundwater abstraction is permitted, the work does not stop there.
A good compliance system should track:
- borewell details
- flow meter readings
- daily or monthly abstraction quantity
- operating hours
- purpose-wise consumption
- water balance
- production-linked water use
- groundwater quality, where required
- rainwater harvesting or recharge measures
- renewal and reporting requirements
- conditions mentioned in the approval or consent
One common problem is this:
The borewell is running.
The plant knows roughly how much water is being used.
But there is no proper reconciliation between:
Groundwater abstracted → Water used → Wastewater generated → Water reused → Water lost
That is where a water balance becomes very useful.
Another important point is the flow meter.
If groundwater use is regulated, the meter should not be treated as just another instrument installed near the borewell.
EHS teams should make sure it is:
- functional
- readable
- periodically checked
- properly recorded
- consistent with operating hours and water-use data
If the flow meter shows 100 KL/day but production, ETP flow and water consumption records indicate something very different, that gap should be investigated.
The same applies to recharge.
Installing a recharge structure is not enough.
Its condition, accessibility, maintenance and actual functioning should also be checked.
A practical groundwater compliance approach is:
Approval → Measurement → Use → Reconciliation → Recharge/Reuse → Records → Review
Common gaps I see are:
- using groundwater without checking applicability of approval
- non-functional flow meters
- incomplete abstraction records
- exceeding permitted quantity
- poor water balance
- weak recharge maintenance
- mismatch between water use and production
- delayed renewal or reporting
- ignoring groundwater-related consent conditions
I have summarised the main compliance points in this whiteboard for EHS and environmental professionals in India.
The exact authority, approval requirement and conditions can vary by location and regulatory status, so the applicable current requirements should always be verified for the specific site.